U38-1 ULTIMATE Freestanding Gas Stove

INSTALLATION

OPTIONAL

REMOTE CONTROL

Use the Regency

®

Remote Control Kit ap-

proved for this unit. Use of other systems may
void your warranty.

The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.

Thermostat Wire Table

FINAL CHECK

Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly. This includes:

1) Clocking the appliance to ensure the correct

fi ring rate (rate noted on label) at 15 minutes.

2) If required, adjusting the primary air to ensure

that the fl ame does not carbon. First allow the
unit to burn for 15 min. to stabilize.

3) Check for proper draft.

CAUTION

Any alteration to the product that
causes sooting or carboning that
results in damage to the exterior
facia is not the responsibility of the
manufacturer.

1) Choose a convenient location on the wall

to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the fi replace to
that location, use Thermostat Wire Table.

2) Connect the wires as per the wiring diagram

above.

CAUTION

Do not connect the millivolt re-

mote control wires to

the 120V wires.

3) Install 3 AAA alkaline batteries in transmitter

and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.

OPTIONAL

WALL THERMOSTAT

A wall thermostat may be installed if desired.
Connect the wires as per the wiring diagrams.
Note that the wires are connected to the "TH"
on the gas valve. Use table below to determine
the maximum wire length:

Note: Preferable if the thermostat is installed
on an interior wall.

Regency

®

offers an optional programmable

thermostat but any 250-750 millivolt rated non-
anticipator type thermostat that is CSA, ULC or
UL approved may be used.

CAUTION

Do not connect the millivolt

wall thermostat wires

to the 120V wires.

14 GA.
16 GA.
18 GA.
20 GA.
22 GA.

50 Ft.
32 Ft.
20 Ft.
12 Ft.

9 Ft.

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size Max. Length