Installation, Optional outside air, Clearances to combustibles – Regency Ultimate U38 Medium Gas Stove User Manual

Page 9

Advertising
background image

Regency

®

U38-1 ULTIMATE Freestanding Gas Stove

9

INSTALLATION

Side View

Rear View

Outside Air Through

Rear of Pedestal

Remove the blanking plate from the rear of the
pedestal cover plate and bend the two tabs
out 90 degrees. Pipe fresh air into the pedestal
area by using duct pipe with a mesh grill at the
outside termination. Attach the pipe to the tabs
with screws.

OPTIONAL

OUTSIDE AIR

Outside air for combustion can be brought in
either through the bottom of the pedestal or
through the rear plate of the pedestal.

For both bottom and rear "outside air" the Ped-
estal Cover Plate must be installed. Loosen the
4 screws on the rear of the pedestal and slide
the cover plate over them. Slide the plate to the
left to center it and tighten down the 4 screws.

Outside Air Through

Pedestal Bottom

Once you have properly marked the position of
your unit as outlined in "General Information"
and "Clearances to Combustibles", cut a prop-
erly sized hole though the fl oor directly under
your pedestal base to the outside. Pipe fresh
air into the pedestal area by using appropriate
metallic duct pipe with a mesh grill at the out-
side termination. Do not remove the knockout.

CLEARANCES TO

COMBUSTIBLES

The clearances listed below are MINIMUM dis-
tances. Measure the clearance to both the appli-
ance and the chimney connector. (The farthest
distance is correct if the two clearances do not
coincide.)
For example, if the appliance is set as
indicated in one of the fi gures but the connector is
too close, move the stove until the correct clearance
to the connector is obtained.

This unit can be installed on a solid combustible
surface like a wood fl oor. This unit can also be
installed directly on carpeting or vinyl when the
bottom pedestal cover plate (provided with unit)
is installed.

This appliance may be installed only with the clear-
ances as shown in the situations pictured. Do not
combine clearances from one type of installation
with another in order to achieve closer clearances.

Use the minimum clearances shown in the diagrams
below for installation with "B" vent.

Minimum ceiling height is 36" / 914 mm from

top of unit.

U38-NG1 & U38-LP1 REFERENCE

DIMENSIONS

C Back Wall to Flue Centerline 10-3/4" / 273 mm

D Side Wall to Flue Centerline 20-1/2" / 520 mm

F Side Wall to Flue Centerline 11" / 280 mm

If further reduced clearances are needed, ob-
tain requirements for construction of a protected
wall from your local building authorities and their
allowable reductions of the listed clearances.

U38-NG1 & U38-LP1 Clearances

A Side Wall to Unit

7-1/2" / 190 mm

B Back Wall to Unit

6" / 155 mm

E Side Wall to Unit

2" / 50 mm