c

Wipe the laser scanner window (1) by
wiping it with a dry, lint-free soft cloth.

d

Put the drum unit and toner cartridge
assembly back in the machine.

e

Close the front cover.

f

Plug the machine’s power cord back into
the AC power outlet first.Turn on the
machine’s power switch.

Cleaning the corona wire

C

If you have print quality problems, clean the
corona wire as follows:

a

Turn off the machine’s power switch.
Disconnect all cables, and then unplug
the power cord from the AC power
outlet.

b

Open the front cover and slowly take out
the drum unit and toner cartridge
assembly.

IMPORTANT

• We recommend that you place the drum

unit and toner cartridge assembly on a
clean, flat surface with a sheet of
disposable paper or cloth underneath it in
case you accidentally spill or scatter toner.

• Handle the toner cartridge carefully. If

toner scatters on your hands or clothes,
wipe or wash it off with cold water at once.

• To prevent damage to the machine

caused by static electricity, DO NOT touch
the electrodes shown in the illustration.

1