3. Take the top half of your column and make sure there is an access hole to tighten down the coupler

onto the column shaft. We cut the top half of our column so that the wire slot lines up with the coupler
screw.

4. Put the Column in a drill press to drill the three holes accurately. If the holes are off the slightest

amount you will have to oblong the holes that are off.

5. Now do the same with the bottom tube using the paper strip labeled 206250 that has the holes

centered. The alignment of this tube will not matter because it is the same all around.