23
Perimeter details
Wall Termination
True Wood
linear panel
finish nails
2 x 4 wood blocking
tee
attach wood blocking to grid
with fastener (see detail)
metal angle
attached to wall
Note: approximately last 3 linear panels attached to wood blocking with wood finishing nails
finish nails
2 x 4 wood blocking
tee
fastener
True Wood
linear panel
Access Door
1
/
2
" wood screws
on both sides
True Wood
linear panel
access panel
assembly
tee
tee
1
/
2
" wood screws
on alternate sides
punched holes
for screws
True Wood
linear panel
DWSS tee
Barrel Vault
Applications
linear
True Wood
linear panel
1
/
2
" wood screw
curved tee
Minimum Radius in DWSS is 39"
screw toward edge
where grid touches panel