UG:013

vicorpower.com

Applications Engineering: 800 927.9474

Page 19

ADAPTIVE LOOP using PRM and VTM

LOCAL SENSE (Single Ended) using PRM

REMOTE SENSE (Differential) using PRM and VTM

SLAVE using PRM

1

2

3

4

5

6

7

8

9

10

ON

OFF

ON

OFF

ON

OFF

ON

OFF

Postion

number

DEFAULT / ADAPTIVE LOOP using PRM

ON

OFF

Figure 9.

Switch configuration

Common features in all modes of operations

n

On / off control to enable and disable the PRM

®

in the presence of input power.

n

Using switch S11 or

n

Open drain MOSFET using external circuitry or function generator

n

Input filtering (inductor and ceramic capacitors)

n

Output filtering (inductor and ceramic capacitors)

n

Sockets for easy installation of input and output electrolytic capacitor

n

Test points for current sensing

n

Kelvin test points for measurement of input voltage, output voltage and

all signal pins of the PRM.

n

Sockets for each test point for easy installation of through-hole components and

solid wires to facilitate the wiring to external circuitry and test equipment.

Figure 9 provides the illustration for how to configure the switch for each operating mode.

2

3

1

S11

S

G

D

SOT 23_3

Q10

0603

R2 1

SGND

T P23

T P24

H23

H26

T P65

T P66

ENABLE

ON / OFF CONTROL

Figure 10.

ON / OFF control