Position on or off connection number, Table 6. switch configuration in local sensing – Vicor VI Chip PRM Evaluation Board User Manual

Page 22

Advertising
background image

UG:013

vicorpower.com

Applications Engineering: 800 927.9474

Page 22

The following table describes the switch configuration.

In this configuration, PRM operates in Remote Sense. PRM module output voltage is
sensed through divider formed by R29 and R31. U11B is configured as buffer as shown
in figure 13 and provides the sense voltage to error amplifier U11A. R33, R41 and R27
are left open, reserved for differential sensing and current sensing. R29 is set to limit
the upper trim range based on a maximum reference voltage of 1.25 V. Note that by
default compensation components are not installed and required for operation. Default
compensation components are provided with the board as described in a later section.

SGND

SGND

VCC

R32

1206

C22

1206

EAO

R33

1206

SGND

R41

1206

+SENSE_B

-SENSE_B

LOCAL SENSE_+

2

3

1

4

8

SO8

U11A

6

5

7

U11B

1206

54.9K

R29

1206

1.27K

R31

1206

1.27K

R42

1206

1K

R36

C21

0603

IMON

R27

1206

H 48

H 47

H 51

H 52

1206

20Ω

R30

H 46

H 45

TP38

TP37

OPEN

OPEN

OPEN

OPEN

OPEN

VREF

To CONTROL NODE
through S10

Preinstalled component
and connections

User installed
component

C19

1206

1206

20K

R28

1206

4.7nF

C20

H 39

H 40

H 43

H 44

H 42

H 41

To PRM +OUT
through S10

AC signal
injection

Figure 13.

Remote Sense: local sensing

(single ended) control circuitry

BLUE highlight =

Pre-installed component

GREEN highlight =

user installed component

Switch

Position

ON or OFF

Connection

Number

1

ON

TRIM pin is shorted to GND and PRM is configured for Remote Sense

Operating mode.

2

ON

CONTROL NODE pin is connected to output of external error amplifier.

3

ON

IFB pin is connected to output of external current sense amplifier to set

constant current limit.

4

ON

REF_EN pin is connected to input of the external voltage reference circuit

to generate voltage reference for external error amplifier.

5

ON

VAUX pin is connected to power VCC of the op-amp and current sense IC.

6

OFF

TM pin of the VTM is not connected to VT pin of the PRM.

7

ON

PRM +OUT pin is connected to local sense (single ended) of the remote

sense control circuitry.

8

Don’t care

9

OFF

See next Remote Sense Operation

10

OFF

See next Remote Sense Operation

Table 6.

Switch configuration

in local sensing