26

2.5 Connections

2.5.1 Bottom panel connections

Figure 9

– Bottom Panel Connections

Ethernet port

The WI-I/O 9-U2 modules provides a standard RJ-45 Ethernet port compliant to IEEE
802.3 10/100 BaseT. This port provides full access to the module, including
configuration, diagnostics, log file download and firmware upload, of both the local and
remote units.

Additionally the Ethernet port can provide network connectivity for locally connected
third-party devices with Ethernet functionality.

USB Device Port for configuration

The WI-I/O 9-U2 module also provides a USB-device (USB-B) connector. This
connector provides configuration of the device and remote configuration access to other
devices in the radio network.

RS-232 port

The WI-I/O 9-U2 module provides an RS-232 serial port, which supports operation at
data rates up to 230,400 baud. This port supports MODBUS protocol.

The RS-232 port is provided by an RJ-45 connector wired as a DCE according to EIA-
562 Electrical Standard.

RJ-45

Signal

Required

Signal name

Connector

1

RI

Ring Indicator

2

DCD

Data Carrier Detect

3

DTR

Y

Data Terminal Ready

4

GND

Y

Signal Common

5

RXD

Y

Receive Data (from WI-I/O 9-

U2)

6

TXD

Y

Transmit Data (to WI-I/O 9-U2)

7

CTS

Clear to Send

8

RTS

Request to Send