160 Series C Custom Firmware

Braking

The P34 - [Stop Mode Select] setting 3, “DC Injection Braking (w/Auto
Shutoff)” function uses a new parameter for current limit during
braking. This allows maximum braking performance.

Table D
Braking Parameters

Five Point V/Hz Curve

V/Hz curves are programmed in the standard drive with P38 - [Boost
Select]. This function has been replaced by a five point V/Hz curve.
The curve can be adjusted using the parameters described in

Table E

.

The ramp will start at the programmed start frequency, but will ramp
down to zero when stopping or reversing (if the start frequency is
non-zero). The voltage will follow a straight line drawn from the start
point to zero frequency and zero voltage.

Parameter
Number

Parameter Name

Min./Max./Default Description

P48

DC Injection Current Limit 1/180/150 %

This limit is only in effect during
DC injection braking.

Breakpoint2

Start Point

Breakpoint1

Base

Maximum