Chapter 5, Specifications, Electrical – Rockwell Automation 150-E SMC Elevator Users Manual User Manual

Page 27: Table 19 - power circuit, Chapter

Advertising
background image

Rockwell Automation Publication 150-UM009D-EN-P - February 2011

27

Chapter

5

Specifications

Electrical

Table 19 - Power Circuit

UL/cUL/CSA

IEC

Rated Operational Voltage 200…600V AC

200…500V~

Rated Insulation Voltage 600V AC

500V~

Di-electric Withstand 2200V AC

2500V~

Repetitive Peak 200…600V AC: 1600

500V~: 1600

Rated Impulse Voltage

6 kV

Overvoltage Category

III

Number of Poles

Equipment designed for 3-phase only

Operating Frequency

50/60 Hz

Controller Utilization Category 32/52/64

AC-53b: 3.5-15:3585

74/104/147

AC-53b: 4.5-30:1770

234

AC-53b: 3.5-30:1770

Overlad Current Range (Amps) Line

Delta

32

6.3...19

10.9...32.9

51

10...30

17...51

64

12.3...37

21.3...64

74

14.3...43

24.7...74

104 20...60

34.7...104

147 28.3...85

49...147

234 34...135

59...234