Table 20 - Control Circuit

Table 21 - Short Circuit Capabilities

UL/cUL/CSA

IEC

Rated Operational Voltage 100...120V AC, 200...240V AC

120~, 240~

Rated Insulation Voltage —

300V~

Di-electric Withstand

3000V

Rated Impulse Voltage

3 kV

Operating Frequency

50/60 Hz

Control Power Requirements 32/52/64

215 mA @ 120 V AC ,
180 mA @ 240 V AC

74/104/147

200 mA @ 120 V AC ,
100 mA @ 240 V AC

234

200 mA @ 120 V AC ,
120 mA @ 240 V AC

Fan Power Requrements 32/52/64

74/104/147

234

20VA

Short Circuit Performance

Type 1

Device Current Rating Maximum Fuse Size & Type

Maximum Available Fault
Rating

32

70 A - RK5

5 kA

125 A - K5

5 kA

51

125 A - RK5

5 kA

200 A - K5

10 kA

64

125 A - RK5

5 kA

200 A - K5

10 kA

74

150 A - RK5

5 kA

250 A - J

10 kA

104

200 A - RK5

5 kA

400 A - J

10 kA

147

250 A - RK5

10 kA

400 A - J

10 kA

234

400 A - RK5

10 kA

450 A - K5

10 kA