The Setup screen appears.

5.

Select Route Mem and press the Right arrow to display the following
choices:
Internal - Load the data to the Dynamix 2500 data collector internal

memory.

Storage Card - Load the data to the SD storage card in the Dynamix

2500 data collector.

6.

Select the destination and press the Left arrow key to save your choice.

7.

When finished, press F4 (Apply).

Initialize the Data Collector before Loading

If data already exists in the data collector but you do not need it anymore, you can
delete the data by initializing the data collector’s memory using the Emonitor
software. Make sure that you no longer need the data before deleting it.

Before you initialize the Dynamix memory, make sure the Emonitor software and
the data collector are properly connected.

There are two ways you can initialize the Dynamix using the Emonitor software,
either automatically before loading a list, or manually at any time. You can also use
the data collector to initialize memory.

TIP

You initialize the Dynamix 2500 data collector internal memory and
memory card separately. This is determined by the Route Memory
setting in the Setup screen.