Multi-channel Measurements Chapter 6

9.

Add the two locations to a group list by double-clicking the Group column
in the Location pane.

The current group number appears in the Group column. Make sure you
assign the locations the same group number. The group is then loaded with
the list to the Dynamix 2500 data collector.

Cross Channel Phase Measurement Definitions on page 185

shows a

typical setup for a cross channel phase measurement.

Figure 8 - Cross Channel Phase Measurement Definitions

10.

Connect the data collector to the computer and load the list to the
Dynamix 2500 data collector.

See

Load Selected Lists to the Data Collector on page 119

for details.

11.

Once you have prepared the Dynamix 2500 data collector for data
collection, select the route and collect the cross channel phase
measurement.

See

Collect a Cross Channel Phase Measurement on page 188

.

Set Up an Offroute Cross Channel Phase Measurement

The Cross Channel Phase Offroute measurement is configured by creating a user-
defined measurement point. The Dynamix 2500 data collector keeps the user-
defined parameters until you collect another measurement point or press F2
(Default) on the Offroute User screen.

See

Create and Collect a User-defined Point on page 152

for more information.

1.

Select Data Collection from the Main Menu and press the Enter key.

The Data Collection screen appears.

2.

Select the route. The Dynamix 2500 data collector always associates
Offroute measurements with a list.