Measurement resolution – Rockwell Automation 1441-DYN25-Z Dynamix 2500 Data Collector User Manual

Page 79

Advertising
background image

Rockwell Automation Publication 1441-UM001B-EN-P - September 2012

79

Setting Up Measurements Chapter 3

You can either select a value from the drop down list, or you can enter a value in
Maximum frequency in the Collection Specification dialog box. If you enter a
value that does not match one of the values above, the Emonitor software uses the
next higher maximum frequency.

Measurement Resolution

The measurement resolution is part of the collection specification (Setup >
Collection). See

Collection Specification Dialog Box on page 75

.

Select the collection specification when you set up the measurement definition.
The Emonitor software and the Dynamix 2500 data collector support these
resolutions.

The values that appear in the Number of lines drop down list in the Collection
Specification dialog box are those for spectrum measurements. The Emonitor
software uses the corresponding number of time samples from the table above for
time measurement definition.

You can calculate the number of time samples from the number of spectral lines
using this formula.

You can calculate the total time required to collect a time waveform measurement
from the Number of lines value and the Maximum frequency value in the
Collection Specification dialog box (Setup > Collections).

Table 23 - Measurement Resolutions

Spectral Lines

Time Samples

100

256

200

512

400

1024

800

2048

1600

4096

3200

8192

6400

16,384

12,800

32,768

25,600

(1)

(1) The Emonitor software does not currently support 25,600 spectral lines and will

not upload this data.

65536

(2)

(2) The data collector is able to take the time samples Offroute but will not upload the

data to the Emonitor software.

time samples

spectral lines 2.56

=