Rockwell Automation 1441-DYN25-MFRF Frequency Response Function Extension Module for the Dynamix 2500 User Manual

Page 24

Advertising
background image

24

Rockwell Automation Publication 1441-UM003A-EN-P - May 2011

Chapter 2 FRF Frequency Response Function Extension Module

The status indicators provide feedback on the hammer hits.

See the Dynamix 2500 Data Collector User Manual, publication

1441-UM001

,

for more information about the status indicators:

If the Accept/Reject option in FRF - Setup was set to Automatic, each

hammer hit is collected and the Dynamix 2500 data collector
automatically determines if the data is correct. If it is not, a message appears
with details on why the hit was rejected.

If Accept/Reject was set to Manual, the hammer and response time

waveforms display for both the hammer and accelerometer outputs, and
then an Accept/Reject prompt appears.

4.

Review the FRF data and either Accept or Reject the hit.

When all the averages are taken, the Taking Data screen updates to show
the FRF magnitude/phase traces.

Table 3 - Status Indicators

Status Indicator

Description

Red

An error, for example, input overrange, during data acquisition.

Amber

Instrument is initializing the measurement.

Green

Instrument is collecting data. In Hammer mode, it is looking for a hit.

Advertising