II. Conversion Steps

b) With the lower part of the conversion module/terminal block assembly attached to the base-plate’s hook/mounting tab, align the module between

the lower and upper horizontal module guides and gently push the upper part of the assembly into the spring locking tab until an audible snap is
heard. NOTE: It may be necessary to adjust the spring locking tab (bend down when mounted) to ensure it fully engages the module. This can
be done using a flat blade screwdriver (refer to Figure 5e).

6) Attach the 1492 Cables to the Conversion Module

Use the following procedure to attach the 1492 interface cable to the conversion module. The function of this cable is to attach the conversion
module to the 1756 I/O module.
a) Find the appropriate cable for the conversion and 1756 I/O module. Refer to Appendix B for a list of compatible cables.

b) Find the conversion module compatible end of the cable. NOTE: Digital cables (molded end) have a keyed connector, and analog cables have a

metal D-shell and a slide-locking assembly.

c) Gently guide the conversion module end of the cable into the conversion module, and firmly press the two components together. Refer to

Figures 6c and 6d.

Adjust spring

locking tab

Figure 5f

Figure 5e

Figure 6b

Figure 6a

Figure 6d

Figure 6c