Heavy duty dynamic braking 29 – Rockwell Automation 1336_F_E_T_S SERIES A CHOPPER BRAKE MODULE User Manual

Page 29

Advertising
background image

Heavy Duty Dynamic Braking

29

1336-5.65 — March, 2007

WA070, WB035 and WC035 Terminal Block, Fuse and Jumper Locations

Fuse F1

Fuse F2

BRAKE MODE

SLAVE MASTER

1

W1

Slave/Master

Jumper W1

BRAKE MODE

SLAVE MASTER

W1

VOLT SELECT

380V 460V

1

W2

Brake Frame Ground

(Connect to Earth Ground)

GND

BARCODE

Brake Module Board

DS1

DS1

DC Power ON Light

DS2

Brake ON Light

DS2

E12

E11

E9

E10

1

2

3

4

5

6

Terminal Block TB1

Max/Min Wire Size = 8.4

/

0.8 mm

2

(8

/

18 AWG)

Max Torque = 1.81 N-m (16 lb.-in.)

Terminals E9-E12

Max/Min Wire Size = 33.6

/

2.1 mm

2

(2

/

14 AWG)

Max Torque = 3.96 N-m (35 lb.-in.) for 5.3-2.1 mm

2

(10-14 AWG)

4.52 N-m (40 lb.-in.) for 8.4 mm

2

(8 AWG)

5.09 N-m (45 lb.-in.) for 21.2-13.3 mm

2

(4-6 AWG)

5.65 N-m (50 lb.-in.) for 33.6 mm

2

(2 AWG)

VOLT SELECT

380V 460V

1

W2

Input Voltage Select
Jumper W2

(WB035 Units Only)

1

Advertising