Figure 2 locating the ul mark on the fuse label – Rockwell Automation 1394 Shunt Modules Fuse Replacement Kit User Manual

Page 2

Advertising
background image

1394 Shunt Modules Fuse Replacement Kit

Publication 1394-6.6 — March 1999

3.

Remove the fuse from the fuse holder with the fuse puller tool.

4.

Insert the new Bussmann 700V 40A fuse (FWP40A14F) or equivalent
into the 1394-SR10A fuse holder.

5.

Apply power to your system.

Replacing the 1394-SR9A,

-SR9AF, -SR36A, and -

SR36AF Fuse and Label

To replace the 1394-SR9A, -SR9AF, -SR36A, and -SR36AF shunt module
fuse and label:

1.

Remove power from your system including the shunt module.

2.

Examine the fuse label for the UL mark.

Figure 2

Locating the UL Mark on the Fuse Label

!

ATTENTION: This system may have multiple
sources of power. More than one disconnect switch
may be required to de-energize the system. To avoid
shock hazard or personal injury, verify that all power
has been removed before proceeding.

!

ATTENTION: This product contains stored energy
devices. To avoid hazard of electrical shock, verify that
all voltage on the capacitors has been discharged before
attempting to service, repair, or remove this unit. You
should only attempt the procedures in this document if
you are qualified to do so and familiar with solid-state
control equipment and the safety procedures in
publication NFPA 70E.

1394-SR36A/36AF

1394 Digital Servo Controller

3600W Shunt Module

1394-SR9A/9AF

1394 Digital Servo Controller

300W Shunt Module

BULLETIN 1394 3600W SHUNT MODULE

ALLEN-BRADLEY

FOR USE WITH 1394-SJT22-X SYSTEM MODULE

CAT.

PART

SER.

INPUT DC

INPUT AC

BULLETIN 1394 300W SHUNT MODULE

ALLEN-BRADLEY

FOR USE WITH 1394-SJT22-X SYSTEM MODULE

CAT.

PART

SER.

INPUT DC

INPUT AC

Fuse Label

Fuse Label

Advertising