1394 Shunt Modules Fuse Replacement Kit

3

Publication 1394-6.6 — March 1999

3.

Locate the door panel latch(es).

Figure 3

1394 Shunt Modules Door Latches

4.

Undo the door panel latch(es).

5.

Open the door panel.

6.

Locate the fuse holder.

Figure 4

Locating the Fuse Holder for the 1394 Shunt Modules

If your 1394-SR9A, -
SR9AF, -SR36A, or -
SR36AF shunt
module:

You need a:

Has the UL mark

Bussmann 600V DC 50A fuse
(FWP50A14F) or equivalent.

Does not have the UL
mark

Bussmann 600V DC 40A fuse
(170N2013) or equivalent.

1394-SR36A/36AF

1394 Digital Servo Controller

3600W Shunt Module

1394-SR9A/9AF

1394 Digital Servo Controller

300W Shunt Module

BULLETIN 1394 3600W SHUNT MODULE

ALLEN-BRADLEY

FOR USE WITH 1394-SJT22-X SYSTEM MODULE

CAT.

PART

SER.

INPUT DC

INPUT AC

BULLETIN 1394 300W SHUNT MODULE

ALLEN-BRADLEY

FOR USE WITH 1394-SJT22-X SYSTEM MODULE

CAT.

PART

SER.

INPUT DC

INPUT AC

Door Latch

Door Latch

Door Latch

1394-SR36A/36AF

1394-SR9A/9AF

Fuse Holder