For more information refer to our web site – Rockwell Automation 1394 Shunt Modules Fuse Replacement Kit User Manual

Page 4

Advertising
background image

Publication 1394-6.6 — March 1999

193591

1999 Rockwell International. All Rights Reserved. Printed in USA

7.

Remove the fuse from the fuse holder with the fuse puller tool.

8.

Close the door panel.

9.

Secure the door panel.

10. Attach the new fuse label over the existing fuse label on the front door panel

of the shunt module.

Figure 5

New Fuse Label Attached to the 1394 Shunt Modules

11. Apply power to your system including the shunt module.

For more information refer to our web site:

www.ab.com/motion

If your 1394-SR9A, -
SR9AF, -SR36A, or -
SR36AF shunt
module:

Replace the fuse with a:

Has the UL mark

Bussmann 600V DC 50A fuse
(FWP50A14F) or equivalent.

Does not have the UL
mark

Bussmann 600V DC 40A fuse
(170N2013) or equivalent.

1394-SR36A/36AF

1394 Digital Servo Controller

3600W Shunt Module

1394-SR9A/9AF

1394 Digital Servo Controller

300W Shunt Module

BULLETIN 1394 3600W SHUNT MODULE

ALLEN-BRADLEY

FOR USE WITH 1394-SJT22-X SYSTEM MODULE

CAT.

PART

SER.

INPUT DC

INPUT AC

BULLETIN 1394 300W SHUNT MODULE

ALLEN-BRADLEY

FOR USE WITH 1394-SJT22-X SYSTEM MODULE

CAT.

PART

SER.

INPUT DC

INPUT AC

Fuse Label

Fuse Label

FOR FUSE REPLACEMENT USE:
BUSSMAN CAT. NO.

FOR FUSE REPLACEMENT USE:
BUSSMAN CAT. NO.

R

R

For more information refer to our web site: www.ab.com/motion

For Rockwell Automation Technical Support information refer to: www.rockwellautomation.com/support or Tel: (1) 440.646.3434

Advertising