Nema 12 enclosed installation – Rockwell Automation 1329I CE Filter Option Kit User Manual

Page 5

Advertising
background image

1329I Integrated Drive/Motor CE Filter Option Kit

5

5. Reconnect display ribbon cable and reinstall cover.

NEMA 12 Enclosed
Installation

Use the cross-reference table below to verify that the correct filter has been
selected for your CE compatible drive.

Filter Selection

Filter Enclosure Dimensions

ATTENTION:

The cover screws must be securely tightened in

order to properly ground the cover. Verify that all four cover screws
are tight before applying power to the unit. Failure to observe this
precaution could result in severe bodily injury or loss of life.

Filter Catalog
Number

Series

Ratings

Use with Bulletin 1329I
Series B Drive/Motor

1329I-JLF1

A

115/230 VAC
Single Phase
14 Amps

1329I-BJ
1329I-BK

1329I-JLF3

A

230/460 VAC
Three Phase
9 Amps

1329I-BL
1329I-BM

152.0

(6.0)

29.0

(1.13)

10.0

(0.38)

273.0

(10.75)

225.0

(8.87)

292.0
(11.5)

113.0

(4.46)

3.0

(0.10)

mm

(in)

Advertising