Bulletin 1329i ce filter option specifications – Rockwell Automation 1329I CE Filter Option Kit User Manual

Page 8

Advertising
background image

Publication 1329I-5.4 – January, 2000

P/N 194395 (01)

Copyright 2000 Rockwell International Corporation. Printed in USA

Bulletin 1329I CE Filter
Option Specifications

1329I-NLF1

1329I-NLF3

1329I-JLF1

1329I-JLF3

Input Voltage

115/230 VAC

230/460 VAC

115/230 VAC

230/460 VAC

Input Phases

Single Phase

Three Phase

Single Phase

Three Phase

Frequency

50/60 Hz

Rated Current

14 Amps

9 Amps

14 Amps

9 Amps

Power Dissipation

5 Watts

Leakage Current (Worst Case)

0.5 mA

Weight

0.33 Kg (0.73 lb)

0.45 Kg (0.99 lb)

4.72 Kg (10.41 lb)

4.89 Kg (10.78 lb)

Enclosure

Internal

NEMA 12/IP 65

Operating Temperature

0° to 40°C (32° to 104°F)

Storage Temperature

-40° to 85°C (-40° to 185°F)

Relative Humidity

5% to 95%, non-condensing

Vibration

1 G operational, 2.5 G non-operational

Shock

15 G operational, 30 G non-operational

Altitude

1000 meters (3300 feet) without derating. For every 91.4 meters (300 feet) above

1000 meters, derate current by 1%. Above 3000 meters (10,000 feet), consult your

Allen-Bradley Sales Office.

International Standards and
Approvals

UL

®

LISTE

D 966X

IND CONT EQ

UL508C

UL

®

LISTE

D 966X

IND CONT EQ

C

CSA 22.2

EMC Directive 89/336

LV:

EN 50178, EN 60204

EMC: EN 61800-3, EN 50081-1, EN 50082-2