1204 Terminator (Class 1, Division 2)

1336 PLUS/PLUS II/IMPACT™/FORCE
Maximum Motor Cable Length Restrictions (500-600 Volt Drives)

1

Lengths are given in meters and (feet)

NR = Not Recommended

1

Values shown are for nominal input voltage and drive carrier frequency of 2 kHz. Consult factory regarding operation at carrier frequencies above 2 kHz. Multiply values
by 0.85 for high line conditions.

2

Information not available at time of printing.

Type A Motor Characteristics: No phase paper or misplaced phase paper, lower quality insulation systems, corona inception voltages between 850 and 1000 volts.

Type B Motor Characteristics: Properly placed phase paper, medium quality insulation systems, corona inception voltages between 1000 and 1200 volts.

1329R/L Motors:

These AC variable speed motors are “Power Matched” for use with Allen-Bradley drives. Each motor is energy efficient and designed
to meet or exceed the requirements of the Federal Energy Act of 1992. All 1329R/L motors are optimized for variable speed operation
and include premium inverter grade insulation systems which meet or exceed NEMA MG1. Part 31.40.4.2.

PowerFlex 70/700/700H

See the PowerFlex Reference Manual, Volume 1,
publication PFLEX-RM001 available online at
www.rockwellautomation.com/literature.

PowerFlex 700S

See the PowerFlex Reference Manual, Volume 2,
publication PFLEX-RM002 available online at
www.rockwellautomation.com/literature.

Drive
Frame

Drive kW (HP)

Motor kW (HP)

w/1204-TFB2 Terminator

w/1204-TFA1 Terminator

With
Allen-Bradley
1329R/L Motors

Motor Type

Motor Type

A

B

1329R/L

A

B

Any Cable

Any Cable

Any Cable

Any Cable Any Cable

Any Cable

A4

0.75 (1)

0.75 (1)

NR

182.9 (600)

335.3 (1100)

NR

61.0 (200)

182.9 (600)

0.37 (0.5)

NR

182.9 (600)

335.3 (1100)

NR

61.0 (200)

182.9 (600)

1.5 (2)

1.5 (2)

NR

182.9 (600)

335.3 (1100)

NR

61.0 (200)

182.9 (600)

1.2 (1.5)

NR

182.9 (600)

335.3 (1100)

NR

61.0 (200)

182.9 (600)

0.75 (1)

NR

182.9 (600)

335.3 (1100)

NR

61.0 (200)

182.9 (600)

0.37 (0.5)

NR

182.9 (600)

335.3 (1100)

NR

61.0 (200)

182.9 (600)

2.2 (3)

2.2 (3)

NR

182.9 (600)

335.3 (1100)

NR

61.0 (200)

182.9 (600)

1.5 (2)

NR

182.9 (600)

335.3 (1100)

NR

61.0 (200)

182.9 (600)

0.75 (1)

NR

182.9 (600)

335.3 (1100)

NR

61.0 (200)

182.9 (600)

0.37 (0.5)

NR

182.9 (600)

335.3 (1100)

NR

61.0 (200)

182.9 (600)

3.7 (5)

3.7 (5)

NR

182.9 (600)

335.3 (1100)

NR

61.0 (200)

182.9 (600)

2.2 (3)

NR

182.9 (600)

335.3 (1100)

NR

61.0 (200)

182.9 (600)

1.5 (2)

NR

182.9 (600)

335.3 (1100)

NR

61.0 (200)

182.9 (600)

0.75 (1)

NR

182.9 (600)

335.3 (1100)

NR

61.0 (200)

182.9 (600)

0.37 (0.5)

NR

182.9 (600)

335.3 (1100)

NR

61.0 (200)

182.9 (600)

B

5.5-15 (7.5-20)

5.5-15(7.5-20)

91.4 (300)

182.9 (600)

2

NR

61.0 (200)

182.9 (600)

C

18.5-45 (25-60)

18.5-45 (25-60)

91.4 (300)

182.9 (600)

2

NR

61.0 (200)

182.9 (600)

D

56-93 (75-125)

56-93 (75-125)

91.4 (300)

182.9 (600)

2

NR

61.0 (200)

182.9 (600)

E

112-224 (150-X300)

112-224 (150-X300)

91.4 (300)

182.9 (600)

2

NR

61.0 (200)

182.9 (600)

F

187-336 (250-450)

187-336 (250-450)

91.4 (300)

182.9 (600)

2

NR

61.0 (200)

182.9 (600)

G

224-448 (300-600)

224-448 (300-600)

91.4 (300)

182.9 (600)

2

NR

61.0 (200)

182.9 (600)

H

522-597 (700-800)

522-597 (700-800)

91.4 (300)

182.9 (600)

2

NR

61.0 (200)

182.9 (600)

Advertising