How to select the ppr of a pulse encoder – Rockwell Automation 1397 Pulse Encoder Interface Installation Inst. User Manual

Page 3

Advertising
background image

1397 Pulse Encoder Interface Card

3

1397-5.13 June, 1997

One pulse/scan is required to meet the specified drive speed regulation
listed in the 1397 User Manual. For a drive scan time of 0.02 seconds,
the card requires a minimum of (50) pulses-per-second from a pulse
encoder. Using a minimum motor speed of 25 RPM:

PPR

1

=

[1]

×

[60]

=

120 PPR

——————

25

×

[0.02]

Step 2 — Determine the maximum allowable pulse encoder PPR.

To leave adequate "head room" for possible motor over speeding at
the motor’s rated nameplate speed, the card’s "head room" frequency
should not exceed 73kHz, the card’s maximum frequency.

where:

PPR

2

= The Maximum Allowable Pulse Encoder

PPR

N

2

= P.041 [Max Motor Speed]

PPR

2

=

73,000

×

60 Sec/Min

———————————

N

2

PPR

1

PPR

req

PPR

2

where

PPR

req

= The PPR Required for the Application

Step 3 — Pick a PPR for the application.

Pick a PPR for the application between the values calculated in Steps
1

&

2.

Step 4 — Calculate the pulse encoder’s required frequency at P.041

[Max Motor Speed].

Using the value selected in Step 3, calculate the pulse encoder
frequency at P.041 [Max Motor Speed].

where:

Freq

req

= The Pulse Encoder’s Required Frequency

PPR

req

= The PPR Required for the Application

Freq

req

=

N

2

×

PPR

req

———————

60

Freq

req

80%

×

Freq

PE

where

Freq

PE

= The Pulse Encoder’s Maximum Rated Nameplate Frequency.

Step 5 — Confirm that the pulse encoder frequency

80% of the pulse

encoder’s maximum rated nameplate frequency.

To ensure that the pulse encoder has adequate "head room" for motor
overspeeding, confirm that the pulse encoder’s required frequency is

80% of the pulse encoder’s maximum rated nameplate frequency.

How to Select the PPR of
a Pulse Encoder

(continued)

Advertising