Rockwell Automation Publication 1305-5.2.2 - September 2013

5

1305 Adjustable Frequency AC Drive

HIM Display Panel
Descriptions

HIM Control Panel
Descriptions

Item

Name

Description

Escape

When pressed, the ESCape key will cause the programming system to go back one
level in the menu structure.

Select

Pressing the SELect key alternately moves the cursor to the next active area. A
flashing first character indicates which line is active.

Increment/
Decrement

These keys are used to increment and decrement a value or scroll through different
groups or parameters.

Enter

When pressed, a group or parameter will be selected or a parameter value will be
entered into memory. After a parameter has been entered into memory, the top line
of the display will automatically become active, allowing another parameter (or
group) to be chosen.

Item

Name

Description

Start

The Start key will initiate drive operation if no other control devices are sending a Stop
command. This key can be disabled by the [Logic Mask] or [Start Mask].

Stop

If the drive is running, pressing the Stop key will cause the drive to stop, using the selected
stop mode. See [Stop Select] in the User Manual.
If the drive has stopped due to a fault, pressing this key will clear the fault and reset the
drive. See [Flt Clear Mode], [Logic Mask], and [Fault Mask].

Jog

When pressed, jog will be initiated at the frequency set by [Jog Frequency], if no other
control devices are sending a Stop command. Releasing the key will cause the drive to stop,
using the selected stop mode. See [Stop Select], [Logic Mask], and [Jog Mask].
Important: If the drive is running prior to issuing a jog command, the jog command will be
ignored. A start command from another source will override the jog command.

Change
Direction

Pressing this key will cause the drive to ramp down to zero Hertz and then ramp up to set
speed in the opposite direction. The appropriate Direction LED will illuminate to indicate the
direction of motor rotation. See [Logic Mask] and [Direction Mask]. Note that the factory
default for control of the reverse function is the reverse input at TB2. To enable the HIM
control of the reverse function, change ‘Bit 0’ of the [Direction Mask] parameter to ‘0’ to
disable the reverse function at TB2.

Direction LEDs
(Indicators)

These LEDs illuminate to indicate the direction of motor rotation.

Increment/
Decrement
Arrows
(only available
with digital
speed control
)

Pressing these keys will increase or decrease the HIM frequency command. An indication of
this command will be shown on the visual Speed Indicator LEDs. The drive will run at this
command if the HIM is the selected frequency reference. See [Freq Select 1/2].
Pressing both keys simultaneously stores the current HIM frequency command in HIM
memory. The Speed Indicator LEDs will flash momentarily to indicate a successful save (if
speed is above 20 percent). Cycling power or connecting the HIM to the drive will set the
frequency command to the value stored in HIM memory.

Analog Speed
Potentiometer

If the Analog Speed Potentiometer option has been ordered, the Increment/Decrement keys
and Speed Indicator will be replaced by the pot.

Rotating ‘Forward’

Rotating ‘Reverse’

Changing Direction, Decelerating ‘Reverse’, will begin
to Accelerate ‘Forward’.

Changing Direction, Decelerating ‘Forward’, will begin
to Accelerate ‘Reverse’.

OFF

Steady ON

Steady ON

OFF

Flashing

Steady ON

Steady ON

Flashing