1305 series c parameter list – Rockwell Automation 1305 FRN. 6.XX Reference Guide User Manual

Page 6

Advertising
background image

6

Rockwell Automation Publication 1305-5.2.2 - September 2013

1305 Adjustable Frequency AC Drive

1305 Series C Parameter List

Speed Indicator
LEDs
(only available
with digital
speed control
)

Illuminates in steps to give an approximate visual indication of the commanded speed.
If the Analog Speed Potentiometer option has been ordered, the Increment/Decrement keys
and Speed Indicator LEDs will be replaced by the pot.

Item

Name

Description

Group/
Parameter

No.

Units

Min.
Value

Max.
Value

Default
Value

Group/
Parameter

No.

Units

Min.
Value

Max.
Value

Default
Value

Metering

Analog Invert

84

Text

(1)

Disabled

Output Current

54

0.01 Amps

0.00

2x Drive Output Current

4-20 mA Loss Sel

81

Text

(1)

Stop/Fault

Output Voltage

1

1 Volt

0

Maximum Voltage

Stop Select

10

Text

(1)

Ramp

Output Power

23

0.01 kW

0.00

2x Rtd. Dr. Output Power —

DC Hold Time

12

0.1 Sec

0.0

150.0

0.0

DC Bus Voltage

53

1 Volt

0

410…230V Drive

DC Hold Volts

13

1 Volt

0

25% of Max DRV

0

815…460V Drive

DB Enable

11

Text

(1)

Disabled

Output Freq.

66

0.01 Hz

0.00

Maximum Frequency

Motor Type

41

Text

(1)

Induc/Reluc

Freq. Command

65

0.01 Hz

0.00

+400.00

0.00

Compensation

52

Text

(1)

Comp

MOP Hz

42

0.01 Hz

0.00

400.00

Frequency Set

Drive Temp

70

1 deg. C

0

100

Freq Select 1

5

Text

(1)

Adapter 1

Last Fault

4

Numeric

0

Max. Fault No.

Freq Select 2

6

Text

(1)

Remote Pot

% Output Power

3

1%

0

200% Drive Rated Power —

Jog Frequency

24

0.1 Hz

0.0

400.0

10.0

% Output Curr.

2

1%

0

200% Rtd. Dr. Out. Curr.

Prst/2nd Accel

26

Text

(1)

Preset

Setup

Upper Presets

72

Text

(1)

Disabled

Input Mode

21

Text

(1)

Three Wire

Accel Time 2

30

0.1 sec

0.0

3600.0

5.0

Freq Select 1

5

Text

(1)

Adapter 1

Decel Time 2

31

0.1 sec

0.0

3600.0

5.0

Accel Time 1

7

0.1 sec

0.0

3600.0

10.0

Preset Freq 1

27

0.1 Hz

0.0

400.0

10.0

Decel Time 1

8

0.1 sec

0.0

3600.0

10.0

Preset Freq 2

28

0.1 Hz

0.0

400.0

20.0

Base Frequency

17

1 Hz

40

400

60

Preset Freq 3

29

0.1 Hz

0.0

400.0

30.0

Base Voltage

18

1 Volt

25% of DRV 100% of Max DRV

Max DRV

Preset Freq 4

73

0.1 Hz

0.0

400.0

40.0

Maximum Voltage 20

1 Volt

25% of DRV 110% of Max DRV

Max DRV

Preset Freq 5

74

0.1 Hz

0.0

400.0

50.0

Minimum Freq

16

1 Hz

0

120

0

Preset Freq 6

75

0.1 Hz

0.0

400.0

60.0

Maximum Freq

19

1 Hz

40

400

60

Preset Freq 7

76

0.1 Hz

0.0

400.0

0.0

Stop Select

10

Text

(1)

Ramp

Skip Freq 1

32

1 Hz

0

400

400

Current Limit

36

1%

20% of DRC 150% of DRC

150% of DRC

Skip Freq 2

33

1 Hz

0

400

400

Overload Mode

37

Text

(1)

No Derating

Skip Freq 3

34

1 Hz

0

400

400

Overload Current

38

0.1 Amps

20% of DRC 115% of DRC

115% of DRC

Skip Freq Band

35

1 Hz

0

15

0

Sec Curr Limit

141

1%

0% of DRC

150% of DRC

0% of DRC

MOP Increment

22

1 Hz/Sec

0.00

255.00

1.00

Adaptive I Lmt

149

Text

(1)

Enabled

Analog Filter

144

Text

(1)

100%

Advanced Setup

Feature Select

Minimum Freq

16

1 Hz

0

120

0

Run On Power Up

14

Text

(1)

Disabled

Maximum Freq

19

1 Hz

40

400

60

Reset/Run Tries

85

Numeric

0

9

0

Base Frequency

17

1 Hz

40

400

60

Reset/Run Time

15

0.1 Sec

0.5

30.0

1.0

Base Voltage

18

1 Volt

25% of DRV 100% of Max DRV

Max DRV

S Curve Enable

57

Text

(1)

Disabled

Break Frequency

49

1Hz

0

120

30

S Curve Time

56

0.1 Sec

0.0

300.0

0.0

Break Voltage

50

1 Volt

0

50% of Max DRV

Dr. Size Dep.

Language

47

Text

(1)

Approp. Lang.

Maximum Voltage 20

1 Volt

25% of DRV 110% of Max DRV

Max DRV

Cable Length

143

Text

(1)

Short

DC Boost Select

9

Text

(1)

Break Point

Rated Slip

146

0.1 Hz

0.0

5.0

2.0

Start Boost

48

1 Volt

0

25% of Max DRV

Dr. Size Dep.

Slip Comp Adder

148

0.01 Hz

0.00

5.00

Run Boost

83

1 Volt

0

25% of Max DRV

0

IR Comp %

147

1%

0%

150%

Drv. Depend.

PWM Frequency

45

0.1 kHz

2.0

8.0

4.0

(Table continued on next page.)

Advertising