Dimensions, Mounting your external shunt resistor – Rockwell Automation 1394-SR10A External Shunt Resistor Kit User Manual

Page 2

Advertising
background image

2

1394 External Shunt Resistor Kit

Publication 1394-5.6 — December 1999

Dimensions

The dimensions of the 1394-SR10A shunt resistor assembly and fuse
block are shown in the figure below.

Figure 1

1394-SR10A Shunt Resistor Assembly

Mounting Your External Shunt

Resistor

To mount your 1394-SR10A Shunt Resistor:

1. Remove all 24V control power, contactor enable power, and 360/

480V AC input power from the system.

2. Wait at least two minutes for the DC Link to discharge.

!

ATTENTION: These resistors can reach temperatures
in excess of 350

°

C (662

°

F). Appropriate guarding must

be provided to avoid the hazard of shock or burn and
ignition of flammable material. Install per local codes.

380

(14.96)

342

(13.46)

165.1

(6.5)

Wire length = 203 (8.0)

17

(0.67)

Wire length = 1524 (60.0)

Wire length = 1524 (60.0)

Wire length = 203 (8.0)

82.5

(3.25)

Dimensions are in millimeters and (inches)

Depth = 100 (3.94)

Fuse holder

+

+

+

+

82.6

(3.25)

36.5

(0.375 +/- 0.010)

(1.48)

9.5

19.1

(0.75)

9.6

(0.38)

38.1

(1.50)

38.1

(1.50)

Dimensions are in millimeters and (inches)

External Shunt Resistor

Fuse Holder

!

ATTENTION: To avoid the hazard of
electrical shock or injury, verify that all power
has been disconnected before continuing.

!

ATTENTION: The 1394 contains stored
energy devices. To avoid the hazard of electrical
shock or injury, verify that the bus voltage is
zero before continuing.