Connecting 1394-dclms together, Figure 5 locating the power plug, Figure 6 removing the power plug – Rockwell Automation 1394-DCLM DC Link Module User Manual

Page 4

Advertising
background image

Publication 1394-5.11 — December 1999

4

Installing Your 1394 DC Link Module

Figure 5

Locating the Power Plug

If you are linking two systems together, install the second 1394-
DCLM in the second system. The total wire distance between 1394-
DCLMs cannot exceed 3 meters (9.84 ft).

Connecting 1394-DCLMs Together

You can connect two 1394 systems together using either a 1.5 meter
(4.92 ft) cable (catalog number 1394-CPDC-0015) or 3 meter
(9.84 ft) cable (catalog number 1394-CPDC-0030).

To connect 1394-DCLMs together:

1. Remove the power plug from the front underside of each 1394-

DCLM using a phillips screwdriver.

Figure 6

Removing the Power Plug

Power Plug

DC Link
Module

1394 Digital Servo Controller

System Module

Allen-Bradley

Power Plug

DC Link
Module

1394 Digital Servo Controller

System Module

Allen-Bradley

Screws