DeviceNet ArmorBlock™ Network Powered 16-input Module 5

Publication 1732D-IN007B-EN-E - November 2011

The DeviceNet network uses advanced network technology, producer/consumer
communication, to increase network functionality and throughput. Visit our web site
at 

www.ab.com/networks

for producer/consumer technology information and updates.

Catalog Number Explanation

The catalog number 1732D-IBDPM12MND refers to a DeviceNet 24V DC 8-port,
16-input mini-style network connector module.

Install the Module

To install the module:

Set the node address.

Mount the module.

Connect the cordsets.

Set the Node Address

Valid node addresses are 00…63.

Set the node address using either the rotary switches, RSNetWorx for DeviceNet,
DeviceNetManager, or another software configuration tool. Setting the switches at 64…99
lets the software have address control.

Each module is shipped with their node address set at 63. Remove the caps on the front of
the module to access the switches. The two switches are:

X10 (most significant digit) – left side of module

X1 (least significant digit) – right side of module

To reset the node address:

1. Rotate the switches using a small-bladed screwdriver.

2. Line up the small black dot on the switch with the number setting you wish

to use.

3. Cycle power.