2 - install and wire the modules, Determine the module’s power requirements, Chapter 2 – Rockwell Automation 1746-FIO4V SLC 500 Fast Analog I/O/ User Manual User Manual

Page 11: Install and wire the modules, Chapter

Advertising
background image

11

Publication 1746-UM009B-EN-P - September 2007

Chapter

2

Install and Wire the Modules

This chapter describes procedures to install fast analog I/O modules in
an SLC 500 system. The procedures include the following tasks.

• determine the module’s power requirements
• determine compatibility with other I/O modules
• configure input channels
• select the I/O rack slot
• install the module
• consider when wiring

using system wiring guidelines

grounding the cable

determining cable length

• minimize electrical noise interference
• wire the module
• minimize ground loops
• label the terminal block

Determine the Module’s
Power Requirements

Analog modules require power from the 5V dc and 24V dc backplane
power supplies of the SLC 500 system. This table shows the backplane
power requirements for fast analog I/O modules.

Use this table to compute the module’s portion of total load on the
modular system power supply.

For more information, refer to SLC 500 Systems Selection Guide,
publication 1747-SG001.

Current Load

Catalog Number

Current at 5V dc

Current at 24V dc

1746-FIO4I

55 mA

150 mA

1746-FIO4V

55 mA

120 mA

Advertising