Briggs & Stratton 203721GS User Manual

Page 22

Advertising
background image

22

BRIGGSandSTRATTON.COM

PROBLEM

CAUSE

CORRECTION

Compressor is not
supplying enough air to
operate accessories.

1. Prolonged excessive use of air.

2. Compressor is not large enough for air

requirement.

3. Hole in hose.

4. Check valve restricted or leaks air.

5. Restricted air intake filter.

1. Decrease amount of air used.

2. Check the accessory requirement. If it is higher

than the CFM or pressure supplied by your air
compressor, you need a larger capacity air
compressor.

3. Inspect and replace if required.

4. Contact trained service technician.

5. Clean or replace air intake filter.

Engine will not start;
lacks power; starts and
runs rough; or engine
speed constantly
fluctuates (hunts).

1. Engine switch set to Off.

2. Fuel valve is in Off position.

3. Dirty air cleaner.

4. Out of fuel.

5. Stale or contaminated fuel, or water in

fuel.

6. Spark plug wire not connected to spark

plug.

7. Bad spark plug.

8. Excessive fuel is present in the air/fuel

mixture causing a “flooded” condition.

9. Excessively rich fuel mixture.

10. Intake valve stuck open or closed.

11. Engine has lost compression.

12. Carburetor is running too rich or too

lean.

1. Set switch to On.

2. Turn fuel valve to On position.

3. Clean or replace air cleaner.

4. Wait two minutes and fill fuel tank.

5. Drain fuel tank and carburetor; fill with fresh

fuel.

6. Connect wire to spark plug.

7. Replace spark plug.

8. Wait 5 minutes and re-start engine.

9. Contact Authorized service facility.

10. Contact Authorized service facility.

11. Contact Authorized service facility.

12. Contact Authorized service facility.

Engine shuts down when
running.

Out of fuel.

Wait two minutes and fill fuel tank.

Compressor will not run.

1. Tank pressure exceeds pressure switch

“cut-in” pressure.

2. Start valve on idle control valve has not

unloaded head pressure.

1. Engine will go from idle to full speed when

tank pressure drops below “cut-in” pressure
setting.

2. Drain pressure by opening start valve. If the

toggle does not open, pull safety valve ring.
Replace idle control valve.

Advertising