Creating a controller – Rockwell Automation 1757-SWKIT5000 Getting Started with ProcessLogix R500.1 Quick Start User Manual
Page 9
Advertising
Getting Started with ProcessLogix R500.1 9
Publication 1757-QS500A-EN-P - October 2002
Creating a Controller
The first step in configuring your hardware is to create a controller.
1. In Control Builder, select File⇒New⇒Controllers⇒CPM-Control Processor
Module.
You see the CPM Parameters dialog box (CPM = PLX52):
2. In the CPM Parameters dialog box, select the following:
IMPORTANT
Be careful to enter the CPM Parameters correctly. You will not be able to
change all of them after they are entered.
in this field:
enter/select:
CPM Name
CPM0101
Network Type
ControlNet
Driver Name
AB_PCIC-1
Supervisory MAC Address
01 (for the ControlNet 1756-CNB card)
Supervisory Slot Number
00
CPM Slot Number
01