Application, Installation instructions – Bakers Pride DRG-40 User Manual

Page 28

Advertising
background image

® U.S. Registered Trademark
Copyright © 1999 Honeywell Inc. • All Rights Reserved

INSTALLATION INSTRUCTIONS

69-1226-2

VR8105, VR8205, and VR8305

Direct Ignition Combination

Gas Controls

APPLICATION

These direct ignition gas controls are used in gas-fired
appliances with up to 415 ft

3

/hr. capacity at 1 in. wc

pressure drop (8.5 m

3

/hr at 0.25 kPa) on natural gas.

They include a manual valve, two automatic operators
and a pressure regulator.

These gas controls are available in a range of valve
capacities, see Table 1. (Table 2 provides gas capacity
conversion factors.) The suffix letter indicates
temperature range and regulator type, see Table 3.

Table 1. Valve Capacity

a

a

Capacity based on 1000 Btu/ft

3

, 0.64 sp gr natural gas at 1 in. wc pressure drop (37.3 MJ/m

3

, 0.64 sp gr natural gas

at 0.25 kPa pressure drop).

b

Capacity is reduced by 5 percent when using an outlet screen.

c

Valves are guaranteed at only 77 percent of the rating.

d

Minimum regulation for LP gas is 15,000 Btuh.

e

Minimum regulation for LP gas is 40,000 Btuh.

f

Minimum regulation for LP gas is 50,000 Btuh.

Table 2. Gas Capacity Conversion Factor.

Table 3. Model Number Suffix Letter Designation.

Model

Size Inlet-

Outlet (in.)

AGA Certified

Capacity for Natural

Gas

AGA Certified Minimum

Regulation for

Natural Gas

AGA Certified Maximum

Regulation for

Natural Gas

ft

3

/hr

m

3

/hr

ft

3

/hr

m

3

/hr

ft

3

/hr

m

3

/hr

VR8105

1/2 x 1/2

85

2.3

10

d

0.4

120

3.4

VR8205

150

4.2

20

e

0.6

200

5.7

VR8305

b,c

240

6.8

30

f

0.8

340

9.6

VR8305

b,c

1/2 x 3/4

270

7.6

370

10.5

VR8305

b,c

3/4 x 3/4

300

8.5

415

11.8

Gas

Specific

Gravity

Multiply Listed

Capacity By

Manufactured 0.60

0.516

Mixed

0.70

0.765

Propane

1.53

1.62

Model No.

Suffix
Letter

Ambient

Temperature

Range

Pressure Regulator

Type

A

0°F to 175°F
(-18°C to +79°C)

Standard

C

Step-opening

H

Slow Opening

K

-40°F to +175°F
(-40°C to +79°C)

M

Standard

P

Step-opening

Q

Two-stage

R

Convertible

69-1226-2.fm Page 1 Thursday, November 13, 2003 12:50 PM

Advertising