Wiring – Bakers Pride DRG-40 User Manual

Page 33

Advertising
background image

VR8105, VR8205, AND VR8305 DIRECT IGNITION COMBINATION GAS CONTROLS

69-1226—2

6

Fig. 5. Proper use of wrench on gas control with and without flanges.

Fig. 6. Top view of gas control.

Wiring

Follow the wiring instructions furnished by the appliance
manufacturer, if available, or use the general instructions
provided below. When these instructions differ from the
appliance manufacturer, follow the appliance
manufacturer instructions.

All wiring must comply with applicable electrical codes
and ordinances.

Disconnect power supply before making wiring
connections to prevent electrical shock or equipment
damage.

1. Check the power supply rating on the gas control

and make sure it matches the available supply.
Install a transformer and other controls as required.

2. Connect the control circuit to the gas control

terminals. See Fig. 7 and 8.

3. Adjust thermostat heat anticipator to 0.50A rating

stamped on valve operator.

APPLY WRENCH
FROM TOP OR
BOTTOM OF GAS
CONTROL TO
EITHER SHADED AREA

WHEN FLANGE IS NOT USED

APPLY WRENCH
TO FLANGE ONLY

WHEN FLANGE IS USED

M3084A

HI-LO
ADJUSTMENT SCREWS
(UNDER CAP)

REGULATOR
VENT COVER

INLET

INLET

OUTLET

M10967A

HI

LO

OUTLET
PRESSURE
TAP

WIRING
TERMINALS (2)

INLET
PRESSURE TAP

PRESSURE REGULATOR
ADJUSTMENT (UNDER
CAP SCREW)

GAS CONTROL KNOB

TWO-STAGE
PRESSURE
REGULATOR
MODEL

69-1226-2.fm Page 6 Thursday, November 13, 2003 12:50 PM

Advertising