Startup and checkout, Gas control knob settings, Perform gas leak test – Bakers Pride DRG-40 User Manual

Page 34: Turn on system, Turn on main burner, Warning, Gas leak test

Advertising
background image

VR8105, VR8205, AND VR8305 DIRECT IGNITION COMBINATION GAS CONTROLS

7

69-1226—2

Fig. 7. Typical wiring connections for 24 volt control

in S87 Direct Ignition System.

Fig. 8. Typical wiring connections with 24 volt control

in S89 Direct Ignition System.

STARTUP AND CHECKOUT

WARNING

Fire or Explosion Hazard.
Can cause property damage, severe injury
or death.

1. Do not force the gas control knob on the

appliance. Use only your hand to turn the gas
control knob. Never use any tools.

2. If the knob does not operate by hand, the

control should be replaced by a qualified
service technician.

Gas Control Knob Settings

Gas control knob settings are as follows:

• OFF: Prevents pilot and main gas flow through the

control.

• ON: Permits gas to flow into the control body. Under

control of the thermostat and direct ignition module,
gas can flow to the main burners.

NOTE: Controls are shipped with the gas control knob

in the ON position.

Perform Gas Leak Test

WARNING

Fire or Explosion Hazard.
Can cause property damage, severe injury
or death.
Perform Gas Leak Test every time work is done
on a gas system.

IMPORTANT

Do not spray soap and water solution on the
gas control. Do not use an excessive amount of
soap and water solution to perform the gas leak
test. These can damage the control.

Gas Leak Test

1. Paint pipe connections upstream of the gas control

with rich soap and water solution. Bubbles indicate
a gas leak.

2. If a leak is detected, tighten the pipe connections.
3. Light the main burner. Stand clear of the main

burner while lighting to prevent injury caused from
hidden leaks that could cause flashback in the
appliance vestibule.

4. With the main burner in operation, paint the pipe

joints (including adapters) and the control inlet and
outlet with rich soap and water solution.

5. If another leak is detected, tighten the adapter

screws, joints, and pipe connections.

6. Replace the part if a leak cannot be stopped.

Turn On System

Rotate the gas control knob counterclockwise

to

ON.

Turn On Main Burner

Follow appliance manufacturer instructions or turn
thermostat up to call for heat.

24V

24V (GND)

S87 CONTROL MODULE

ALARM

VALVE

VALVE

GND

TEMPERATURE
CONTROLLER

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.

ALTERNATE LIMIT CONTROLLER LOCATION.

MAXIMUM IGNITER-SENSOR CABLE LENGTH: 3 ft. [.9 m] OR LESS.

3 A REPLACEABLE FUSE.

ALARM TERMINAL PROVIDED ON SOME MODELS.

M9043

MV

MV

L1

(HOT)

L2

1

2

1

2

3

DUAL VALVE
COMBINATION
GAS CONTROL

Q347 IGNITER-SENSOR

BURNER

4

4

5

IGNITER-SENSOR AND
BURNER GROUND

3

5

ALARM, IF USED

WHITE

BLUE

BLACK

BLUE

HOT
SURFACE
IGNITER-
SENSOR

VALVE
VALVE (GND)

24V
TH-W
24V (GND)

GND (BURNER)

S89C,G,J/S890C,G,J
HOT SURFACE
IGNITION CONTROL

L2

HSI

L1

HSI

LIMIT
CONTROLLER

BURNER
GROUND

THERMOSTAT
OR CONTROLLER

DUAL VALVE
COMBINATION
GAS CONTROL

POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED. MAKE SURE L1 AND L2 ARE NOT
REVERSED; THIS WOULD PREVENT FLAME DETECTION.

ALTERNATE LIMIT CONTROLLER LOCATION.

SEN TERMINAL AND Q354 FLAME SENSOR ON D MODELS ONLY.

M9047

MV

MV

L1

(HOT)

L2

VENT
DAMPER PLUG

1

2

1

2

3

3

SEN

Q354 FLAME
SENSOR

69-1226-2.fm Page 7 Thursday, November 13, 2003 12:50 PM