If main burner does not come on with call for heat, Instructions to the home-owner, To turn on appliance – Bakers Pride DRG-40 User Manual

Page 38: Stop: read the warnings above before proceeding, Turning off the appliance, Caution, Warning

Advertising
background image

VR8105, VR8205, AND VR8305 DIRECT IGNITION COMBINATION GAS CONTROLS

11

69-1226—2

CAUTION

Equipment Damage.
Can burn out valve coil terminals.
Never apply a jumper across (or short) the valve
coil terminals, even temporarily.

After servicing, verify proper system operation.

If Main Burner Does Not Come On With

Call For Heat

1. Confirm the gas control knob is in the ON position.
2. Adjust thermostat several degrees above room

temperature.

3. Using ac voltmeter, measure across MV terminals

at gas control.

4. If voltage is incorrect or not present, check control

circuit for proper operation.

5. If proper voltage is present, replace gas control.

INSTRUCTIONS TO THE

HOME-OWNER

WARNING

Fire or Explosion Hazard.
Can cause property damage, severe injury,
or death.
Follow these warnings exactly:

1. Before lighting, smell around the appliance for

gas. Be sure to smell next to the floor because
LP gas is heavier than air. If you smell gas:

(a) •Turn off the gas supply at the appliance

service valve. On LP gas systems, turn
off the gas supply at the gas tank.

(b) •Do not light any appliances in the

house.

(c) •Do not touch electrical switches or use

the phone.

(d) •Leave the building and use a neigh-

bor’s phone to call your gas supplier.

(e) •If you cannot reach your gas supplier,

call the fire department.

2. Replace the gas control in the event of any

physical damage, tampering, bent terminals,
missing or broken parts, stripped threads, or
evidence of exposure to heat.

IMPORTANT

Follow the operating instructions provided by
the heating appliance manufacturer. The
information below describes a typical control
application, but the specific controls used and
the procedures outlined in your appliance
manufacturer instructions can differ, requiring
special instructions.

To Turn ON Appliance

STOP: Read the Warnings Above Before

Proceeding

1. The lighting sequence on this appliance is

automatic; do not attempt to manually light the
main burner.

2. If the furnace does not come on when the

thermostat is set several degrees above room
temperature, set the thermostat to its lowest setting
to reset the safety control.

3. Remove the burner access panel if provided on

your appliance.

Turn the gas control knob clockwise

to OFF.

4. Wait five minutes to allow any gas in the

combustion chamber to vent. Then if you smell
gas, STOP! Follow Step 1 in the Warning above. If
you do not smell gas, continue with the next step.

If you do not smell gas, turn knob on gas control
counterclockwise

to ON.

5. Replace the burner access panel.
6. Reset the thermostat to the desired temperature.
7. If the appliance does not turn on, turn the gas

control knob to OFF and contact a qualified service
technician for assistance.

Turning Off the Appliance

Vacation Shutdown

Set the thermostat to the desired room temperature while
you are away.

Complete Shutdown

Turn off power to the appliance. Turn off the gas supply
to the appliance. Turn gas control knob clockwise

to OFF. Appliance will completely shut off.

Follow the procedure in the Instructions to the
Homeowner section above to resume normal operation.

69-1226-2.fm Page 11 Thursday, November 13, 2003 12:50 PM