18 High-Speed Counter Module

Publication 1746-IN011C-EN-P - April 2005

Single-Ended Wiring (Discrete Devices)

IMPORTANT

• This diagram shows the sensors operation from a common

power supply. Separate power supplies for each circuit can
be used.

• The resistor (R1) value depends on the power supply value

(VS). The table on page 17 provides the resistor values for
typical power supply values. These resistors must be
located at the module end of the cable.

• The pull-up resistor (R2) value depends on the power

supply value (VS). The table on page 16 provides the
resistor values for typical power supply values. These
resistors must be located at the sensor end of the cable.

1 2 3 4

A(+)

A(-)

B(+)

B(-)

Z(+)

Z(-)

R1

R2

VS
OUT

COM

VS

OUT

CO M

VS

OUT

CO M

+VDC

COM

proximity sensor
with sourcing output

photoelectric sensor with
open collector sinking output

solid-state
switch

(5V output)

Power
Supply

Module Inputs

SW1

ON

OFF

(All switches OFF)