Limit switch wiring, 19 f – Rockwell Automation 1746-HSCE High-Speed Counter Module Installation Instructions User Manual

Page 19

Advertising
background image

High-Speed Counter Module 19

Publication 1746-IN011C-EN-P - April 2005

Limit Switch Wiring

24V dc Hard Contact

12V dc Hard Contact

5V dc Solid State

ATTENTION

Connect only one LS input range at a time, or the module will
be damaged.

+

-

3 2 1

Hard Contact Limit Switch

HSCE module

JW1

Jumper placed
for 10 ms filtering

Do not connect LS (5V dc) or
LS (12V dc) Terminals

24V dc

VS

COM

LS (24V dc)

LS (12V dc)

LS (5V dc)

LS COM

+

-

3 2 1

Hard Contact Limit Switch

HSCE module

JW1

Jumper placed for
10 ms filtering

Do not connect LS (5V dc) or
LS (12V dc) Terminals

12V dc

VS

COM

LS (24V dc)

LS (12V dc)

LS (5V dc)

LS COM

+

-

3 2 1

Solid State Limit Switch

HSCE module

Do not connect LS (12V dc) or
LS (24V dc) Terminals

Jumper placed
for 300 µs
filtering

JW1

5V dc

VS

COM

LS (24V dc)

LS (12V dc)

LS (5V dc)

LS COM

COM

OUT

VS