Limit switch wiring, 19 f – Rockwell Automation 1746-HSCE High-Speed Counter Module Installation Instructions User Manual
Page 19
High-Speed Counter Module 19
Publication 1746-IN011C-EN-P - April 2005
Limit Switch Wiring
24V dc Hard Contact
12V dc Hard Contact
5V dc Solid State
ATTENTION
Connect only one LS input range at a time, or the module will
be damaged.
+
-
3 2 1
Hard Contact Limit Switch
HSCE module
JW1
Jumper placed
for 10 ms filtering
Do not connect LS (5V dc) or
LS (12V dc) Terminals
24V dc
VS
COM
LS (24V dc)
LS (12V dc)
LS (5V dc)
LS COM
+
-
3 2 1
Hard Contact Limit Switch
HSCE module
JW1
Jumper placed for
10 ms filtering
Do not connect LS (5V dc) or
LS (12V dc) Terminals
12V dc
VS
COM
LS (24V dc)
LS (12V dc)
LS (5V dc)
LS COM
+
-
3 2 1
Solid State Limit Switch
HSCE module
Do not connect LS (12V dc) or
LS (24V dc) Terminals
Jumper placed
for 300 µs
filtering
JW1
5V dc
VS
COM
LS (24V dc)
LS (12V dc)
LS (5V dc)
LS COM
COM
OUT
VS