Power supply & relay connections, Appendix b, Appendix – Rockwell Automation 1440-PK02-05M2 XM-720 Machine Monitor User Manual

Page 57

Advertising
background image

57

Publication GMSI10-UM001C-EN-E - June 2011

Appendix

B

Comparing Connections Between the 5802
and the XM-720

This appendix compares the connections between the 5802 monitor to those
of the XM-720 Machine Monitor.

Power Supply & Relay
Connections

Table B.1 defines the power supply, alarm relay and control connectors for the
5802, and the comparable connectors on the XM-720.

Table A.1 Power Supply & Relay Connections

5802 XM-720

Power Supply &
Relay

Description

TB1

Description

1

Line (Black)

L

AC Input Line

2, 3, 4, or 5

Neutral

N

AC Input Neutral

Chassis ground lug

Ground

E

AC Earth Ground

6

Close on Trip Alarm

10

Trip Relay NO

7

Trip Alarm Common

11

Trip Relay Common

8

Open on Trip Alarm

12

Trip Relay NC

9

Close on Warning Alarm

7

Warning Relay NO

10

Warning Alarm Common

8

Warning Relay Common

11

Open on Warning Alarm

9

Warning Relay NC

12

Open on Fault Alarm

4

Fault Relay NO

13

Fault Alarm Common

5

Fault Relay Common

14

Close on Fault Alarm

6

Fault Relay NC

15

Remote Reset Momentary Switch

13

Reset Relay Switch

16

Return for Remote Reset and
Setpoint Multiplier Switch

14

Switch RTN

Advertising