Note: The filter is used to ascertain whether the recording device is in
Record or just spooling or playing back. According to this information a
log is started or not. Use the incremental record run filter for most EXT
LTC recording situations. The lanc status bit Rec / stop can be used to
verify record status using the LANC as Rec. Run. TC source. Input high
and input low are for using a Camera on/off signal.
eg: red light signal to ascertain recording status.

Note: The TC spot check is a spot entry of record run TC against TOD
made at a certain interval after the recording has started. It is used to
extrapolate timecode values at the beginning of a log where Rec. Run.
TC can be incorrect during cassette run up or stopping. Here the spot
check time after log begin can be set.

SYS INFO here the system info is displayed

ALL 601
Serial number…….
Software version…....

MICRO SD Here the Flash card details are shown

Manufactrurer ID: 2
Product name:

SD512

Size:

488 MB


LOG

LOGGING

This job logs external timecode to internal TOD on a flash card and can
also output TOD as Ext LTC with usebits containing cassette, event
number etc



GEN Here all aspects of the generator TC can be set ( see TCO menu)

Framerate, Userbits, startup time offset, jam source, edit, etc.

MODE Here the log mode can be selected

DISABLED