Ambient Lanc Logger - ALL601 User Manual

Page 18

Advertising
background image

18

RED Logging filter and TC spot check can be set ( logging mode)
INPUT TC FILTER See table

TC SPOT CHECK 5, 7, 10 sec after REC begin

Setting

Record In

Record Out

Record-Run

Consecutive Frs. 2 to 22 in the
same second.

Same value timecode in 2
consecutive frames
( timecode stopped)

Incremental
Record Run

Consecutive Frs. 2 to 22 in the
same second.
In addition the following
critera must be fulfilled

• Cassette number has changed
• Timecode value is larger than

the last Rec.Run. time out value

Same value timecode in 2
consecutive frames
( timecode stopped)

LANC-Status
( “rec” on off
status)

LANC-Status changes from any
status to „rec“

LANC-Status changes form
„rec status to any status

Input High
“Rec” on Off
signal

LowHigh Transition

HighLow Transition

Input Low
Rec” on Off
signal

HighLow Transition

LowHigh Transition


Note: The filter is used to ascertain whether the recording device is in
Record or just spooling or playing back. According to this information a
log is started or not. Use the incremental record run filter for most EXT
LTC recording situations. The lanc status bit Rec / stop can be used to
verify record status using the LANC as Rec. Run. TC source. Input high
and input low are for using an Camera on/off signal, eg red light signal to
ascertain recording status.

Note: The TC spot check is a spot entry of record run TC against TOD
made at a certain interval after the recording has started. It is used to
extrapolate timecode values at the beginning of a log where Rec. Run.
TC can be incorrect during cassette run up or stopping. Here the spot
check time after log begin can be set.

SYS INFO here the system info is displayed

ALL 601
Serial number…….
Software version…....

MICRO SD Here the Flash card details are shown

Manufactrurer ID: 2
Product name:

SD512

Size:

488 MB

Advertising