19. Grounding

Ensure that all protective plastic coating is removed from

panels.

A. Install Angled Batten strips along interior top of Vertical

panels using #8 3/4" Metal screws (Install Angled Batten

strips along interior bottom of Vertical panels if Modular
Building has Floor panels). Install Braided copper wire at
every Speed-Lok location for Ceiling end panels using #8
2-1 /2” Metal screws (Install wires at Speed-Lok locations

for Floor panels if equipped). Install Metal screws in line
with Speed-Lok holes and at least 3" from edge of panel.

B. If Modular Building does not have a Bally aluminum roof,

install exterior Batten strips using #B 3/4" Metal screws.

C. Install #8 2-1 /2" Metal screws at Speed-Lok locations on

both legs of Corner panels. Install Metal screws at the
same height of Speed-Loks and at least 3" from edge of
Corner panel.

20. Broken or stripped locks

A. The panel contained the lock must be slid away from adjacent

panels in order to obtain adequate working space. First check for
any obstructions (dirt, foam, etc) once you have unlocked a panel

reset the cam stop by turning the lock fully back to it’s original
position. If the hook is broken or stripped replacements can be
found in Miscellaneous Parts Box#1.

B. Position the lock wrench on the hex rod and turn clock-wise until

the locking arm protrudes. See Figure 13.

C. Place your hand near the bend in the wrench as shown in Figure

5 and use a lift-up motion. This will produce a clamping action
on the hex rod. While doing this, pull forward until the rod is free

of the panel. The locking arm will then drop free.

D. Hold the new locking arm in position. Make sure the hook of the

arm faces in the proper direction. See Figure 14

E. Insert the new hex rod into the lock hole. Care must be taken to

insert the notched end of the rod. The end to be inserted has a
notch located 1” from the end. This notch acts as a stop so the
rod will not be inserted too far.

F. Align the hex rod with the hex hold of the locking arm; gently tap

it until the notch stops against the locking arm.

G. Replace and refasten the panel in its original position.