7.3 Installing the Fan Frame Assembly

1. First remove the fan guard.
2. Install the frame in the appropriate side and screw

the back braces to the side wall using the same
stainless steel sheet metal screws.

3. Plug in the Air Probe (see connector at top of

picture).

4. Install the two shorter side trim angles on each side

by screwing them to the walls.

5. Replacing the front cover will capture the side trim

pieces between the front cover and the frame.

6. Place the Top Fan Trim Piece between the same

front cover and the frame.

7.4 Installing the Condensate Drain

1. A tube must be installed to drain condensate from

each coil assembly.

2. Find the pan, which is approximately four inches

above floor level on the coil frame. Locate the 90°
Elbow beneath it.

3. You must supply a drain line starting from the ¾” NPT

plastic elbow. You may plumb the line to the front,
rear, or side, as per your convenience. You may use
plastic tubing, PVC pipe, or other pipe. If you are
installing a NW1000, you may join the two runs or
plumb them separately.

4. Drill a hole in the appropriate panel. Caulk the

hole(s) after finishing the plumbing.