Cable connections, Hooking up the system, Installing refrigeration – Bally Refrigerated Boxes 1000 Northwind Blast Chiller User Manual

Page 13: Setting the ceiling plenum

Advertising
background image

13

*The priority should be in that order, if the Coil Top Trim holes won’t match up when the plenum is
screwed to the Front, unscrew the Coil Frame from the wall and shift it over until it fits. The Fan trim piece
can shift side to side with respect to the frame, and you can redrill the holes in the back wall.

8.

Cable Connections

• All of the interior wiring is done utilizing

color-coded, twist-lock, watertight plugs
and type J thermocouple plugs. Make sure
all plugs bottom out.

• All interior wiring must be done before the

ceiling plenum is installed.


9.

Hooking up the System

A properly licensed electrician must next hook
up the system to a shut off attached to a
nearby wall. The electrical specifications are
located on a sticker attached to the controller.

10.

Installing Refrigeration

After the unit has power, the refrigeration
technician can install the refrigeration, running
½” and (usually) 1- 1/8” copper tubing through
the provided hole in the ceiling panel. Make
sure the suction tubing is properly wrapped
with Armaflex, and all work is done in good
practice according to local code. Coils arrive
with a holding pressure of 60 psi nitrogen.

11.

Setting the Ceiling Plenum

The ceiling plenum can now be set in place,
plugged in, and mounted using black thumb
screws. I you have trouble lining up the holes,
remember that the fan side upper trim is
clamped in place and can be slid forward or
backwards, and you can loosen the trim piece
over the coil frame as well. Also remember
that the interior plenum support angle can be
relocated if need be.


8.1 Interior Wiring Color Code

1. TWIST LOCKS from-

Controller to:

Red  defrost heaters
Blue  solenoid valve & defrost

termination

Green  fan motors
Yellow & Brown door junction box

Door junction box to:

White  ceiling plenum light

2. “Grey +” = “Back side of NW1000”. For

example:

Grey & Red  rear defrost heaters


3. Type J Thermocouples

Three Cables Terminating at Outlet

Box(es)

Air probe Cable (single black receptacle)


4. Match all of the plugs together according to

the color code provided. Ty-Wrap all of the
cords to the bases attached to the walls for
that purpose. You will want to leave the
Plenum down for the refrigeration
technician, and it will not matter as far as
the electricity is concerned if you leave the

plenum out of the blast chiller.