4. Perform the Operation & Leakage Tests listed in this

publication.

Every 3,600 operating hours, 100,000 miles or one (1)
year:

1. With the air system pressure at 0 p.s.i., drain collected

contaminants for disposal.

2. Visually check for physical damage to the PuraGuard

QC

filter such as chaffed or broken air hoses and

broken or missing parts.

3. Replace the cartridge (see Maintenance Kits, Figure

5). Do not use the drain valve to remove the cartridge.

4. Check mounting bolts for tightness. Re-torque to 160-

200 in-lbs.

5. Perform the Operation & Leakage Tests listed in this

publication.

The PuraGuard QC

oil coalescing filter has two female

pipe thread air connections: one supply, one delivery —
identified by their relationship to the arrow symbol showing
air flow on the PuraGuard QC

filter top (see Figure 1).

Note: The PuraGuard QC

filter is not recommended to be

used in conjunction with an alcohol evaporator or injector. The
PuraGuard QC

oil coalescing filter will remove the liquid or

aerosol alcohol introduced, defeating the purpose of the
evaporator/injector and requiring the sump to be drained more
often than normal.

FILTER BYPASS

(refer to Figure 4)

If a situation occurs where the ability of the filter to allow air
to pass is impaired and causes a pressure difference of
approximately 20 p.s.i. between the air entering the filter
element and exiting, the filter will move downward against
the spring. The air entering will then be able to bypass the
filter element.

PREVENTIVE MAINTENANCE

Important: Review the warranty policy before performing
any intrusive maintenance procedures. An extended warranty
may be voided if intrusive maintenance is performed during
this period.

Because no two vehicles operate under identical conditions,
maintenance intervals will vary. Experience is a valuable
guide in determining the best maintenance interval for a
vehicle.

Every 300 operating hours, 8,000 miles or one (1)
month:

1. With the air system pressure at 0 p.s.i., use the drain

valve to collect contaminants for disposal. Do not open
the valve beyond shoulder stop. This could loosen the
handle.

2. Visually check the PuraGuard QC

filter for broken or

missing parts.

3. Check mounting bolts for tightness. Re-torque to vehicle

manufacturers guidelines.

FIGURE 4 - BYPASS

FILTER MOVES

DOWNWARDS

AGAINST

SPRING

FORCE

FIGURE 3 - PURAGUARD QC

OIL COALESCING FILTER INSTALLATION SYSTEM WITH AIR DRYER

PuraGuard QC™ oil coalescing filter

Air Dryer

Governor

Air

Compressor

Supply

Reservoir

Primary

Reservoir

Secondary

Reservoir

SPRING

SHOULDER

STOP

Advertising