4. Do not locate the PuraGuard QC

filter near heat

producing components such as the vehicle exhaust and
provide adequate clearance from moving components
e.g. drive shaft, suspension, pitman arm, etc.

5. Locate the PuraGuard QC

filter on the vehicle so that

a minimum of 12 inches of clearance is available
horizontally (90° minimum arc) to allow servicing. This
will permit a strap wrench to be used when replacing
the filter.

6. Be sure that there is sufficient room to attach hoses to

the PuraGuard QC

filter.

7. To permit draining of collected contaminants, at least a

6 inch clearance below the filter is recommended.
Nominal clearance above is required.

8. The PuraGuard QC

oil coalescing filter must be

installed after a properly functioning air dryer. Failure
to locate the filter after an air dryer can cause the filter
to malfunction. An air dryer eliminates certain conditions
in the discharge line that could compromise the design
of the filter.

9. Do not mount the unit in the engine compartment.

MOUNTING THE PURAGUARD QC

OIL

COALESCING FILTER

1. After positioning the PuraGuard QC

oil coalescing filter

according to the installation requirements, mark the
position of the mounting holes on the frame rail. Note:
Check the vehicle manual before drilling a frame
member.

2. Use vehicle manufacturer guidelines for mounting

hardware (use at least grade 5 hardware). Torque to
160-200 in-lbs.

CONNECTING THE AIR HOSES

1. The PuraGuard QC

filter supply and delivery ports are

1/2-14 NPT. Install minimum 1/2 inch inside diameter
air hoses. Install fittings prior to mounting the filter.

2. Hoses must be installed without tight turns that might

cause air flow restrictions. Note: Check that the hose
attachment agrees with the air flow arrow symbol (see
Figure 1).

OPERATIONAL TEST

Build the air system to governor cutout. Shut off the engine.
Using a soap solution, check all hoses and fittings leading

to and from the filter for leakage and integrity. Repair any
excessive leaks - exceeding a 1 inch bubble in 5 seconds
- before restoring vehicle to service.

MAINTENANCE KIT INSTALLATION

KIT DESCRIPTION

A kit is available for cartridge replacement.

VEHICLE PREPARATION

1. Park the vehicle on a level surface and prevent movement

by means other than the brakes.

2. Drain all reservoirs to 0 p.s.i.

3. Drain the contents of the sump into a suitable container

for disposal and then close the drain valve.

DISASSEMBLY AND CLEANING

1. Using a strap wrench, unscrew the cartridge.

2. Remove and discard the cartridge.

INSPECTION

1. Inspect the PuraGuard QC

oil coalescing filter for

broken or missing parts. Replace as necessary.

2. Inspect the drain valve for any build-up that could impair

its function. Clean as necessary.

3. Inspect the housing during filter replacement. Replace

the PuraGuard QC

oil coalescing filter if the body is

becoming clogged with carbon or dirt, clean the supply
and delivery ports if necessary.

ASSEMBLY

1. Tighten the replacement cartridge by turning the cartridge

180° after the cartridge seal touches the aluminum body.
Tighten with a strap wrench, do not tighten by turning
the drain valve.

OPERATIONAL TEST

Build the air system to governor cutout. Shut off the engine.
Using a soap solution, check all hoses and fittings leading
to and from the PuraGuard QC

filter for leakage and

integrity. Repair any excessive leaks - exceeding a 1 inch
bubble in 5 seconds - before restoring vehicle to service.

Advertising