BW2396 © 2004 Bendix Commercial Vehicle Systems LLC All rights reserved. 1/2004 Printed in U.S.A.

PURAGUARD QC

OIL COALESCING FILTER TROUBLESHOOTING CHART

SYMPTOMS

1. More often than normal

(monthly) sump draining
required.

CAUSE

REMEDY

A. PuraGuard QC

oil

coalescing filter installed
in incorrect position in
system.

B. Alcohol injector in

system.

C. Air dryer malfunction.

D. Compressor malfunction.

2. Bypass feature not

working.

A. Supply and delivery air

connections reversed.

A. Reverse hose connections.

A. See figure 3.

B. The PuraGuard QC

filter is not recommended

to be used in conjunction with an alcohol
evaporator or injector. [The PuraGuard QC

filter will remove the liquid or aerosol alcohol
introduced, defeat the purpose of the evaporator/
injector and require the sump to be drained more
often than usual.]

C. Check the air dryer.

D. Check the compressor.

3. Oil in the system.

A. Supply and delivery air

connections reversed.

B. Sump not drained

regularly.

C. Cartridge maintenance

interval exceeded.

D. Air dryer malfunction.

E. Compressor malfunction.

A. Reverse hose connections.

B. Drain the sump every 300 operating hours, 8,000

miles or one (1) month. (Draining can be done
more frequently if desired.)

C. Use a maintenance kit to replace the cartridge

every 3600 operating hours, 100,000 miles or
one (1) year whichever is less.

D. Check the air dryer.

E. Check Compressor.