Diagnostic trouble codes, Dtcs) – Bendix Commercial Vehicle Systems TABS-6 ADVANCED MC SD SHEET User Manual

Page 18

Advertising
background image

18

1st

Digit

2nd

Digit

Diagnostic Code

Description

Possible Causes / Repair Information

J1587

(SID/

FMI)

J1939

(SPN/

FMI)

Auxiliary Design Language (ADL) & Auxiliary I/Os

11

1

Auxiliary I/O Error –
AUX WL (#7)

• Check for corroded/damaged wiring or connectors between the ECU

and ABS Indicator Lamp.

• Check pin X1-5 of the ECU ‘Power’ connector for the following:
– Pin not pushed back.
– Correctly wired to the ABS Indicator Lamp (Pin X1-5 – supply)
– Shorted to ground, V

bat

or other ECU pins.

• Verify the ABS Indicator Lamp is properly grounded and not burnt

out.

• After repairs — or if no issues are found — clear the diagnostic code.
• If the diagnostic code persists, contact your local Bendix

representative before replacing the TABS‑6 Adv MC module.

152/12

612/12

11

2

Auxiliary I/O Error –
AUX I/O #1

• Check for corroded/damaged wiring or connectors between the ECU

and the auxiliary device.

• Check Pins X2-1 & X2-11 of the ECU ‘In-Out’ (I/O) connector for the

following:

 Pins not pushed back.
 Correctly wired to the auxiliary device (Pin X2-1 – supply, pin X2-11

– ground)

 Shorted to ground, V

bat

or other ECU pins.

• Verify the auxiliary device is properly functioning and rated for

maximum load of ≤ 2 amps.

• After repairs — or if no issues are found — clear the diagnostic code.
• If the diagnostic code persists, contact your local Bendix

representative before replacing the Bendix

®

TABS‑6

Adv MC

module.

152/12

612/12

11

3

Auxiliary I/O Error –
AUX I/O #2

• Check for corroded/damaged wiring or connectors between the ECU

and the auxiliary device.

• Check Pins X2-2 & X2-11 of the ECU ‘In-Out’ connector for the

following:

 Pins not pushed back.
 Correctly wired to the auxiliary device (Pin X2-2 – supply,

Pin X2-11 – ground)

 Shorted to ground, V

bat

or other ECU pins.

• Verify the auxiliary device is properly functioning and rated for

maximum load of ≤ 2 amps.

• After repairs — or if no issues are found — clear the diagnostic code.
• If the diagnostic code persists, contact your local Bendix

representative before replacing the TABS‑6 Adv MC module.

152/12

612/12

11

6

Auxiliary I/O Error –
AUX I/O #3

• Check for corroded/damaged wiring or connectors between the ECU

and the auxiliary device.

• Check Pins X2-3 & X2-12 of the ECU ‘In-Out’ connector for the

following:

 Pins not pushed back.
 Correctly wired to the auxiliary device (Pin X2-3 – supply, pin X2-12

– ground)

 Shorted to ground, V

bat

or other ECU pins.

• Verify the auxiliary device is properly functioning and rated for

maximum load of ≤ 1.5 amps.

• After repairs — or if no issues are found — clear the diagnostic code.
• If the diagnostic code persists, contact your local Bendix

representative before replacing the TABS‑6 Adv MC module.

152/12

612/12

Diagnostic Trouble Codes

(DTCs)

(continued)

Advertising