SYMPTOMS

CAUSE

REMEDY

9. Desiccant material

is being expelled
from the air dryer
purge valve exhaust
(may look like
whitish liquid, paste,
or small beads). –
OR Unsatisfactory
desiccant life.

A. This symptom is almost

always accompanied by
one or more of Symptoms
1, 2, 3, 4 and 6. See the
related causes for these
symptoms.

A. See the related remedies for the causes under

Symptoms 1, 2, 3, 4 and 6*.

B. Air dryer not securely

mounted. (Excessive
vibration.)

B. Vibration should be held to minimum. Add bracket

supports or change the air dryer mounting location
if necessary*.

C. Defective desiccant

cartridge.

C. Replace*.

D. Compressor passing

excessive oil.

D. Check for proper compressor installation; if

symptoms persist, replace compressor*.

E. Air dryer has not purged for

an extended period.

E. Refer to Symptom #7 Causes and Remedies*.

10. “Pinging” noise

excessive during
compressor loaded
cycle.

A. A single cylinder

compressor with high pulse
cycles.

A. A slight “pinging” sound may be heard during

system build up when a single cylinder compressor
is used. If this sound is deemed objectionable, it
can be reduced substantially by increasing the
discharge line volume. This can be accomplished
by adding an additional four feet of discharge line,
or adding a 90 cubic inch reservoir between the
compressor and the Bendix

®

AD-RP

air dryer.

11. The air dryer purge

piston cycles rapidly
in the compressor
unloaded (non-
compressing) mode.

A. Compressor fails to

“unload.”

A. Faulty governor installation: no air line from the

governor to the compressor, or the line is “kinked”
or restricted. Install or repair the air line.

* If desiccant material is being expelled, the cartridge and purge valve must be removed from the air dryer and

the desiccant material must be removed from the interior of the dryer. Clean the interior surfaces of the dryer
and install a new cartridge. Clean and inspect the purge valve before re-installation, or replace with a new purge
valve.

Advertising
This manual is related to the following products: