Bendix Commercial Vehicle Systems AD-IS AIR DRYER AND RESERVOIR SYSTM User Manual

Page 10

Advertising
background image

10

FIGURE 6 -

BENDIX

®

AD-IS

®

AIR DRYER AND RESERVOIR SYSTEM DELIVERY CHECK VALVE

GOVERNOR GASKET

(SPECIAL GASKET,

SEE ASSEMBLY NOTE 6)

GOVERNOR

(NON-ADJUSTABLE,

130 PSI CUT-OUT)

BOLTS

ADAPTER

LARGE

O-RING

SPRING

CHECK VALVE

BODY

SMALL

O-RING

DELIVERY CHECK VALVE CLEANING PROCEDURE
(

Note: This is only required if system pressure does not

build after temporary bypass is completed.)
Refer to Figure 6 throughout the following procedures.

De-pressurize the air brake system following the general

safety precautions outlined elsewhere in this document.

Also, always de-pressurize the air dryer purge reservoir

before servicing the air dryer.
This procedure does not require removal of the Bendix

®

AD-IS

®

air dryer and reservoir from the vehicle.

1. Remove the line from the governor and mark for easy

re-installation.

2. Remove the bolts attaching the governor to the

AD-IS air dryer and reservoir system and retain for

re-assembly.

3. Remove the governor from the air dryer. Be aware that

a short puff of trapped air may vent when the governor is

removed. Retain the governor gasket for re-assembly if

a new governor gasket is not available. Remove and

retain the o-ring from the adapter.

4. The spring/delivery check valve can now be removed.
5. Remove and retain the o-ring from the check valve

body.

CLEANING & INSPECTION
1. Use a suitable solvent to clean all metal parts, and

use a cotton swab to clean the bore (Note: Do not use

abrasives or tools to clean the bore: any scratches

caused may necessitate replacing the Bendix

®

AD-IS

®

air dryer and reservoir system.) Superficial

external corrosion and/or pitting is acceptable.

2. Clean the o-rings with a clean dry cloth. Do not use

solvents.

3. Inspect for physical damage to the bore and the check

valve seat. If the bore is damaged (by scratches etc.

that would prevent delivery check valve from seating),

replace the AD-IS air dryer.

4. Inspect the delivery check valve, o-rings, etc. for wear or

damage. Replace, if necessary, using the check valve

replacement kit available at any authorized Bendix parts

outlets.

5. Inspect all air line fittings for corrosion and replace as

necessary.

Advertising